    FEATURES:

    • Is applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
    • Is applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
    • Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
    • Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
    • With user-friendly interface.
    • Display with 2.8” (320×240) color TFT LCD and red and yellow highlight LED.
    • Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
    • Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.
    • Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.

     

    PERFORMANCE:

    • 1. NIBP monitoring
    • Measurement method: Oscillometry
    • Measurement mode: manual/auto/continuous.
    • Auto measurement interval: adjustable from 1 to 90 minutes.
    • Resolution: 1mmHg.
    • Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
    • Self-check function.
    • Overpressure protection: double protection for software and hardware.

    1) Range:

    • A. Adult:
    • Systolic pressure: 40mmHg~270mmHg
    • Mean pressure: 20mmHg~235mmHg
    • Diastolic Pressure: 10mmHg~215mmHg
    • B. Pediatric:
    • Systolic pressure: 40mmHg~200mmHg
    • Mean pressure: 20mmHg~165mmHg
    • Diastolic Pressure: 10mmHg~150mmHg
    • C. Neonatal:
    • Systolic pressure: 40mmHg~135mmHg
    • Mean pressure: 20mmHg~110mmHg
    • Diastolic Pressure: 10mmHg~100mmHg

    2) Upper and lower limit of alarm:

    • A. Adult:
    • Systolic pressure: 40mmHg~270mmHg
    • Mean pressure: 20mmHg~235mmHg
    • Diastolic Pressure: 10mmHg~215mmHg
    • B. Pediatric:
    • Systolic pressure: 40mmHg~200mmHg
    • Mean pressure: 20mmHg~165mmHg
    • Diastolic Pressure: 10mmHg~150mmHg
    • C. Neonatal:
    • Systolic pressure: 40mmHg~135mmHg
    • Mean pressure: 20mmHg~110mmHg
    • Diastolic Pressure: 10mmHg~100mmHg
    • 2. SpO2 monitoring
    • Continuous real-time measuring.
    • Adopt digital SpO2 technology, which has strong anti-interference capability.
    • Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
    • Standard finger-clip probe for adult , binding probe for neonatal is optional.
      • 1) SpO2 Measuring
      • Range: 35%~100% (Resolution: 1%)
      • Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
      • 2) Pulse Rate Measuring
      • Range: 30bpm~250bpm(Resolution: 1bpm)
      • Accuracy: ±2bpm or ±2%, whichever is greater.
      • 3) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
      • 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

     

    ACCESSORIES:

    • A power cord
    • A power adapter
    • A SpO2 probe
    • An adult NIBP cuff
    • An extending tube for blood pressure

     

    PHYSICAL CHARACTERISTICS:

    • Dimension for prodult: 190(L)×162(W)×240(H)mm
    • Weight: 1.6kg
    • Dimension for packaging: 402(L)×228(W)×320(H)mm