Automatic External Defibrillator AED 100 in Pakistan
-22%₨ 220,000 ₨ 230,000
Add to wishlist
CategoryAED Defibrillators
Description:
AED, or Automated External Defibrillator, is a portable emergency device available to the public, mainly used to treat cardiac arrest.
It can automatically analyze the electrocardiogram obtained through electrodes placed on the patient’s skin and identify shockable heart rhythms. When a shockable heart rhythm is detected, it will automatically perform defibrillation.
It can automatically analyze the electrocardiogram obtained through electrodes placed on the patient’s skin and identify shockable heart rhythms. When a shockable heart rhythm is detected, it will automatically perform defibrillation.
| Product Name | AED Defibrillator |
| Output | Biphasic truncated exponential |
| Energy Sequence(child) | 50J,50J.50J |
| Energy Sequence(Adult) | 150J,200J,200J |
| Charge Time | 6 sec. to 150J8 sec. to 200 J(New battery) |
| Analysis Time | 6 sec |
| Preparation time | The maximum time from the initiation of rhythm analy-sis to readiness for discharge with a new battery. Less than 10 seconds. The maximum time from the initiation of rhythm analy-sis to readiness for discharge after 6 shocks Less than 10 seconds The maximum time from initially switching power on to readiness for discharge. Less than18 seconds. |
| Visual Prompts | LED prompts; Automatic Self-test |
| Controls Four buttons | On/Off, Shock,Adult/child,CPR |
| Output Energy Accuracy | +10% into any impedance from 25 to 175Q |
| The Maximum Voltage | 1400+50V Output disabled when the patient impedance is outside limits 202 to 2002 |
| Battery | Index: Content Part No: CR123A-4×2 Non-rechargeable: 2.8 Ah Capacity: 120 discharges at 200 Joules Shelf Life: (25°C+15C)5 years standby (after installation) |
| Physical | 1.Operating Temperature: 0° to 40°C 2.Operating Humidity: Relative humidity between 30% and 95%(non-condensing) 3.Storage Temperature(without battery): -20°C to 55°C 4.Storage Humidity(without battery): Up to 93%(non-condensing) |

WHY USE AED Defibrillator?
Automated External Defibrillator: To understand AED, we must first understand the cardiac arrest. Cardiac arrest refers to the sudden termination of the heart’s ejaculation function.
The artery beating and the disappearance of the heart sound have caused important organs such as severe brain ischemia and hypoxia and died.
This unexpected sudden death, we are also called sudden death. The main reason is the cardiac arrest caused by ventricular fibrillation.


Be the first to review “Automatic External Defibrillator AED 100 in Pakistan” Cancel reply




Reviews
There are no reviews yet.